47
Current device:dome
RS485 address:1
ID: 0
8 Network Keyboard Operation (based on DH-SD)
Note: all the operations here are based on DH-SD protocol. You can refer to
Chapter eight for PELCO protocol operation.
8.1 Dome and Network Keyboard Connection
Connect dome A cable with Pin 3 or Pin 7 of Keyboard 485 interface. Connect
dome B cable with Pin 8 or Pin 9 of Keyboard 485 Port.
8.2 Network Keyboard Setup before Operation
Before setup please make sure:
• Keyboard and dome cable connections are right.
• Connect dome with power source and connect dome video port with monitor.
• Set PTZ decoder address. (Set 485 address as 1 if decoder address is 1.)
• You have set control point.
When you click ESC, system pops up a warning
dialogue.
Click ENTER to save setup or click ESC to exit.
Note: all the items listed here should be properly set. ID, device name, serial port
and IP are all unique.
ID:*0
Device name: ①
Device type:Dome
Connection:RS485
485 address:1
parity:None
Protocol:DH-SD
Stop bits:1
Baud rate:9600
Data bits:8
Here is for you to set ID, device
name and device type. Click ID to go
to current device connection
interface.
Move cursor to highlight “connection”
and then click ENTER. System goes to
RS485 setup. RS485 address is 1.
Default protocol is DH-SD. After all the
setup, please click ENTER to save
modification.
Save Data?
Yes: ENTER, No:ESC